First, let’s decode the name:
Active from 5:00 AM to 8:00 AM and 6:00 PM to 11:00 PM. EMPTYPROG: All functions off (useful for holiday modes).
16A at 250V AC (cos phi = 1); 10A for inductive loads
The Multi 9 range was more than just a series of circuit breakers; it was a complete ecosystem. It provided comprehensive protection for circuits against overloads and short circuits, combined with numerous signaling functions and accessories. In 1992, Merlin Gerin was acquired by Schneider Electric, and its legacy lives on as the technical foundation for modern ranges like and Resi 9 . Understanding this legacy underscores the quality and engineering behind the IC 2000 P . Merlin Gerin Multi 9 Ic 2000 P Manual
Ensure the sensor is not mounted in a permanently shadowed dark alcove. Damaged or cut sensor wire.
Verify that the ambient light is lower than the set Lux value. Perform a manual override test to verify if the lighting circuit and relay contacts are functional.
The (Ref. 15286) is a sophisticated programmable twilight switch designed to automate lighting circuits in domestic and commercial applications. Combining the functionality of a light-sensitive switch with a programmable timer , the IC 2000 P ensures energy efficiency by operating lighting only when it is both dark and within a scheduled timeframe. First, let’s decode the name: Active from 5:00
Mount the external cell vertically on an exterior wall facing North or North-East.
To prevent the lights from flickering due to temporary shadows, lightning, or car headlights, the IC 2000 P has a built-in time delay. On Delay: Approx. 20 to 80 seconds.
Connect Terminal 6 directly to the live terminal of your lighting load or to the coil terminal (A1) of an external contactor if switching heavy loads. Connect the Neutral wire directly to the lighting load. Commissioning and Calibration Ensure the sensor is not mounted in a
To help me tailor any specific adjustments to this guide, could you share what you are troubleshooting or what type of lighting system you are connecting to this Merlin Gerin switch? Share public link
technical data. # light detection part: same as IC2000. # brightness threshold: adjustable from 2 to. 200 lux. # time switch part: docs.rs-online.com light sensitive switches IC200, IC2000, IC2000P - RS Online 5 Jul 2001 —
The device then combines this time program with the light threshold.
Configure the device according to the specific requirements of your electrical system. Incorrect settings can lead to inadequate protection or unnecessary tripping.