What are you aiming to achieve for your safety function?
The Beckhoff SISTEMA Library is a downloadable data file (typically in .slb or .ssm format) provided by Beckhoff Automation. It contains pre-calculated, verified safety-related reliability values for all of Beckhoff’s TwinSAFE hardware components.
When a machine is audited for a CE mark or OSHA compliance, safety documentation must be bulletproof. Reports generated by SISTEMA using official manufacturer libraries provide immediate compliance transparency to third-party inspectors and safety officers. 4. Seamless Architecture Alignment beckhoff sistema library
Encapsulate the FB_Sistema_Channel inside a function block that also contains your physical safety input mapping (e.g., FB_MyEStop_SafetyCheck ).
Using the Beckhoff SISTEMA library involves a straightforward process: What are you aiming to achieve for your safety function
Enables modeling of safety functions before or after realization. Reliability Data: Provides parameters like cap M cap T cap T cap F sub d cap B sub 10 d end-sub cap D cap C sub a v g end-sub for Beckhoff safety hardware. Validation:
TwinSAFE is Beckhoff's integrated safety solution, which allows safety logic to be programmed within the same system as standard control. It uses "Safety over EtherCAT" (FSoE) for reliable communication. The SISTEMA library extends this capability by providing the necessary . It works alongside the core TwinSAFE functionality, which is accessed through standard TwinCAT libraries like TcTwinSAFE.lib , to enable a complete safety workflow: When a machine is audited for a CE
Call the function block cyclically or on-demand:
Export the final safety documentation as a PDF report for your machine technical file. Best Practices for Safety Design with TwinSAFE
: Built-in safety options for TwinSAFE drive systems (e.g., AX5000 or AX8000 with STO/SS1 functionality).